Handheld dynamometers for muscle strength assessment: pitfalls, misconceptions, and facts
Visits
5113
Marco Antonio Cavalcanti Garciaa,c,d,
Corresponding author
marco.garcia@ufjf.edu.br
garcia@ufrj.br
garcia@eefd.ufrj.br

Corresponding author at: Programa de Pós-Graduação em Ciências da Reabilitação e Desempenho Físico Funcional, Faculdade de Fisioterapia, Universidade Federal de Juiz de Fora, Avenida Eugênio do Nascimento, s/n, Bairro Dom Bosco, Juiz de Fora CEP: 36038-330, MG, Brazil.
, Diogo Simões Fonsecad, Victor Hugo Souzab,c,d
a Programa de Pós-Graduação em Ciências da Reabilitação e Desempenho Físico Funcional, Faculdade de Fisioterapia, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, Brazil
b Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
c Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
d Grupo de Estudos em Neuro Biomecânica, Faculdade de Fisioterapia, Universidade Federal de Juiz de Fora, Juiz de Fora, MG, Brazil
This item has received
Article information
Full Text
Bibliography
Download PDF
Statistics
Full Text

Clinical assessment of muscle function provides important clinical information to help with diagnosis and treatment of patients affected by a variety of neuromusculoskeletal disorders.1,2 In the clinical setting, muscle force output can be measured using handheld dynamometers (HHDs).3,4

However, the measurements obtained with HHDs are commonly misrepresented and/or misinterpreted.5 Reporting the raw force values measured using HHDs as the muscle force, is a misconception. To accurately report muscle force output, the force applied to the HHD needs to be multiplied by the length of the lever arm used to apply the resistance to the limb, and be expressed as a torque or moment of force as determined by the following equation,

where F→ (N, or kg, or pounds) is the force measured by the HHD, and d⊥¯ (meter or inches) is the perpendicular distance (lever arm) from the location where the HHD is placed to the center of rotation of the joint of interest.

There are important clinical considerations to be derived from the above equation. First, the HHD needs to be oriented perpendicular to the limb of interest. Second, it is important to measure the distance between the center of rotation of the joint and the location of the HHD, even when a specific anatomical landmark (eg, above the lateral malleolus) is used, as the lever arm will vary based on the anthropometrical dimensions of each individual. Unfortunately, many published articles report strength data without taking these important methodological issues in consideration.6–8

An understanding of the torque-angle relationship is also necessary when interpreting muscle function as measured with an HHD. The ability to generate a torque at a given joint is based on the length-tension relationship as well as the moment arm of all participating muscles. Therefore, muscle force output (torque) measured for a joint is critically dependent on the joint angle at which the measurement is made. Therefore, the reporting and interpretation of strength data using HHD need to be made with knowledge of that joint angle at which the measurement was made.

Another relevant aspect of strength assessment that is often ignored is consideration of the torque generated by the weight of the body segment itself, which will vary based on body position, anthropometry (size of the person measured), and joint angle used for testing. This is further reason for standardization and complete reporting of testing position – especially when this factor cannot be fully controlled or torque related to the weight of the segment cannot be measured/estimated.

Highlights

Based on the above, we outline recommendations that we judge to be important in evaluating muscle force output or torque using HHD:

  • 1

    Reporting of muscle force output should reflect torque values obtained from the force applied to the HHD multiplied by the length of the lever arm used

  • 2

    Using anatomical references for HHD placement is not a substitute for the measurement of the lever arm as limb length varies among individuals and even within individuals over time when testing children

  • 3

    Careful consideration should be made for the position of the individual and the joint angle used for testing to control for the angle-torque relationship and minimize the influence of weight of the segment on the measurements

Conflict of interest

None.

Acknowledgements

The authors thank Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES) – Finance Code 001. V.H.S. is funded by the Jane & Aatos Erkko Foundation.

References
[1]
W. Durfee, P.A. Iaizzo.
Rehabilitation and muscle testing.
Encyclopedia of medical devices and instrumentation, pp. 62-71
[2]
J.Y. Hogrel, G. Ollivier, C. Desnuelle.
Testing musculaire manuel et quantifié dans les maladies neuromusculaires. Comment assurer la qualité des mesures de force dans les protocoles cliniques?.
Rev Neurol, 162 (2006), pp. 427-436
[3]
T. Stark, B. Walker, J.K. Phillips, R. Fejer, R. Beck.
Hand-held dynamometry correlation with the gold standard isokinetic dynamometry: a systematic review.
[4]
J. Toonstra, C.G. Mattacola.
Test-retest and validity of isometric knee-flexion and –extension measurement using 3 methods of assessing muscle strength.
J Sport Rehabil, 22 (2013), pp. 1-5
[5]
M.A.C. Garcia, V.H. Souza.
The (un)standardized use of handheld dynamometers on the evaluation of muscle force output.
Braz J Phys Ther, 24 (2020), pp. 88-89
[6]
A.W. Andrews, M.W. Thomas, R.W. Bohannon.
Normative values for isometric muscle force measurements obtained with hand-held dynamometers.
Phys Ther, 76 (1996), pp. 248-259
[7]
L.M.T. Daloia, M.M. Leonardi-Figueiredo, E.Z. Martinez, A.C. Mattiello-Svertzut.
Isometric muscle strength in children and adolescents using handheld dynamometry: reliability and normative data for the Brazilian population.
Braz J Phys Ther, 22 (2018), pp. 474-483
[8]
G. Alvarenga, H.D. Kiyomoto, E.C. Martinez, G. Polesello, V.L.D.S. Alves.
Normative isometric hip muscle force values assessed by a manual dynamometer.
Acta Ortop Bras, 27 (2019), pp. 124-128
Copyright © 2020. Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
Idiomas
Brazilian Journal of Physical Therapy
Article options
Tools
en pt
Cookies policy Política de cookies
To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.