Journal Information
Vol. 28. Issue S1.
1st STUDENT SCIENTIFIC CONFERENCE OF THE BRAZILIAN ASSOCIATION FOR RESEARCH AND POSTGRADUATE IN PHYSIOTHERAPY (ABRAPG-FT)
(01 April 2024)
Share
Share
Download PDF
More article options
Vol. 28. Issue S1.
1st STUDENT SCIENTIFIC CONFERENCE OF THE BRAZILIAN ASSOCIATION FOR RESEARCH AND POSTGRADUATE IN PHYSIOTHERAPY (ABRAPG-FT)
(01 April 2024)
172
Full text access
INTRA- AND INTER-RATER RELIABILITY AND AGREEMENT OF STIMULUS ELECTRODIAGNOSTIC TESTS IN POST-COVID-19 PATIENTS WHO EXPERIENCED MODERATE OR SEVERE INFECTION
Visits
111
Isabella da Silva Almeida1, Leandro Gomes de Jesus Ferreira1, Álvaro de Almeida Ventura1, Rita de Cássia Marqueti Durigan1, João Luiz Quagliotti Durigan1
1 Department of Phsycal Therapy, Musculotendine Plasticity Laboratory, University of Brasília (UnB), Brasilia, Distrito Federal, Brazil
This item has received
Article information
Special issue
This article is part of special issue:
Vol. 28. Issue S1

1st STUDENT SCIENTIFIC CONFERENCE OF THE BRAZILIAN ASSOCIATION FOR RESEARCH AND POSTGRADUATE IN PHYSIOTHERAPY (ABRAPG-FT)

More info
Background

Post-COVID-19 patients may have several sequelae, such as neuromuscular electrophysiological disorders (NED), which can be evaluated using the stimulus electrodiagnosis test (SET). However, no information is available about the reliability and agreement of SET-in diagnosing NED in COVID-19 patients.

Objectives

Our aim was to verify the intra- and inter-rater reliability and agreement of SET measurements in the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), tibialis anterior (TA), and gastrocnemius lateralis (GL) of post-COVID-19 participants who experienced moderate or severe infection.

Methods

This is an observational prospective study that evaluated 20 post-COVID-19 patients (10 males and 10 females), age: 44.95±11.07 years, weight: 87.99±19.08kg, height: 1.69±0.09m. Two independent raters took two evaluations using the SET on RF, VM, VL, TA and GL of the right lower limb in each participant. The intra-class correlation coefficient (ICC) and 95% limits of agreement defined the quality and magnitude of the measures.

Results

For intra-rater reliability, all measurements presented correlations classified as high or very high (ICC: 0.71-1.0). For the inter-rater reliability, rheobase, chronaxie, accommodation, and accommodation index presented high or very high correlations, except for the accommodation index of the GL (ICC=0.65), which was moderate.

Conclusion

The reliability of the SET obtained by independent raters was very high, except for the GL accommodation, which presented moderate ICC. Therefore, SET is a reliable tool for evaluating neuromuscular electrophysiological disorders in post-COVID-19 patients.

Implications

The SET test can be a reliable tool to assess NED in post-COVID-19 patients. Our results may improve understanding of peripheral NED assessment and thus guide treatment programs for post-COVID-19 patients.

Keywords:
Chronaxie
Electrodiagnosis
Reliability
Full text is only aviable in PDF

Conflict of interest: The authors declare no conflict of interest.

Acknowledgment: This research was funded by CAPES (Code 001), FAPDF (00193.00000773/2021-72; 00193.00000859/2021-3; 00193.00001222/2021-26), e CNPq (309435/2020-0; 310269/2021-0).

Ethics committee approval: University of Brasília, CAAE: 45043821.0.0000.8093.

Idiomas
Brazilian Journal of Physical Therapy
Article options
Tools
en pt
Cookies policy Política de cookies
To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.